In projects such as industrial facilities, highways and subway tunnels, environmental conditions such as dirt, dust, and moisture in the environment prevent exposure using traditional fire detection technologies. Traditional fire alarm techniques, which are seriously affected by bad environmental conditions, tend to give false alarms and cause substantial overpriced maintenance costs.

A fire system used in industrial facility projects where high protection is demanded is required to have the following criteria in terms of performance and technology.

  • Low maintenance costs and security against false alarms during standard operation.
  • Resistance to dirt and corrosive gases. (environmental factors such as exhaust gases, humidity, dust, dirt)
  • Not affected by high air currents and environmental factors.
  • Immunity to parasite fields. (such as tunnel radio, mobile radio, fan vibration, EMC.
  • No change in sensitivity due to temperature variations. (traffic accumulation, air change etc.)
  • Constant system structure.
  • Stipulating reliable alarm triggering in hazardous situations. Successfully executing the essential precautions in harmony with the firefighting strategy. (Activation of audible and visual warning, taking protective measures such as smoke evacuation and extinguishing, etc.)
  • Detection of radiant and convection heat.
  • Fast and reliable alarm detection before a complete fire breaks out.
  • Capability to accurately transmit specific data such as fire progress direction,alarm zone (stopped, moving in the direction of the device, away from the device) to the firefighters.

AP Sensing - Fiberoptic Fire Detection Systems offers us innovative solutions as an significant milestone that conveys fire safety to a new level in projects such as industrial facilities, highways and metro tunnels.

AP Sensing - Fiberoptic Fire Detection Systems are used as fire detection systems in harsh conditions such as highway tunnels, rail system metro lines, industrial facilities where dust, dirt and humidity are excessive.

AP SENSING

AP Sensing GmbH / A German company propositions solutions for fire detection and energy efficiency capacities with fiber optic technologies. 

AP SENSING

Studies on fiber optic and photon technologies have entered applications in many different areas today. This new technology offers us countless innovations in the field of fire alarm systems. Systems that are very challenging or costly to realize with traditional fire alarm systems can be executed with much simpler and economical solutions with an innovative standpoint.

For challenging projects with applications that are at the forefront in many fields, AP Sensing products have become an indispensable solution, with their ability to perform precise measurements over long distances without any problems and using only passive materials in the field.

AP Sensing, which has 20 years of experience in the field of OTDR measurement technique (optical time domain reflectometry), has entered the field of fire alarm systems with DTS (Distributed Temprature System). AP Sensing is Agilent Technologies' marketing and distribution business for DTS systems, which is the world leader in optical measurement and provides the latest opto-electronic component processing technologies.

Since its foundation, the company, which was established up to produce innovative and reliable solutions in the field of fire detection systems, has been involved in many large and prestigious projects. . AP Sensing carries out all its production and R&D activities in Germany.

AP Sensing - Fiber Optic Fire Detection Systems are designed to reduce the cost of service and maintenance and to ensure optimum reliability, even under the following adverse conditions:

  • Dirt, dust and corrosive atmosphere
  • High humidity and extreme temperature changes
  • Solution vapor and radioactive waves
  • ATEX class explosive dust and gas hazard areas
AP SENSING FIBEROPTIC TEMPERATURE SENSING SYSTEMS

These systems are especially used in difficult conditions such as highway tunnels, rail system metro lines, industrial facilities where dust, dirt and humidity are high.

The system not only detects various forms of fires quickly and reliably, but can also locate the fire with an accuracy of a few meters. Without being affected by the storm, the system can identify not only convection heat waves, but also thermal heat waves.

In addition to all these features, thanks to the capability of the sensor cable to withstand temperatures up to 1000 ° C without losing its tracking capability, the system has the ability to follow the magnitude and expansion direction of the fire for a long time.
Thanks to these features, countermeasures can be managed effectively and essential details can be given to those responsible for the incident, such as fire location, volume, heat evacuation. (This information was obtained in 1: 1 fire tests conducted by the Swedish SP Technical Research Institute.) 

AP Sensing “Linear Heat Series” - the best option for these applications.

Application

Tunnel // Large scale facilities
Cable duct // Transformer // Generator
Conveyor belt // Sil
Suspended ceiling // No access areas
Refrigeration facilities
Mines // Refinery // Floating roof tank
Nuclear power plants //
Garbage treatment-collection facilities

Solution

... just one cable
... highest degree of EMV security
… Not affected by dirt and dust
… Maintenance free
… Unaffected by moisture
… ATEX certified
… Not affected by radioactive and
corrosive media

 

AP Sensing

Environmental conditions such as dirt, dust, and moisture in the environment prevent detection using traditional fire detection systems in projects such as industrial facilities, highways and subway tunnels. Traditional fire alarm techniques tend to give false alarms and cause significantly expensive maintenance costs, which are heavily affected by bad environmental conditions.

In terms of performance and technology, a fire system used in industrial facility projects where high security is needed is required to provide the following requirements:

  • Low maintenance costs and security against false alarms during normal operation.
  • Resistance to dirt and corrosive gases. (environmental factors such as exhaust gases, humidity, dust, dirt)
  • It is not affected by high air currents and environmental factors.
  • Immunity to parasite fields. (such as tunnel radio, mobile radio, fan vibration, EMC.)
  • No change in sensitivity due to temperature fluctuations. (traffic accumulation, air change etc.)
  • Stable system structure.
  • Providing reliable alarm triggering in dangerous situations. Successfully implementing the necessary precautions in accordance with the fire fighting strategy. (Activation of audible and visual warning, taking protective
  • measures such as smoke evacuation and extinguishing, etc.)
  • Detection of radiant and convection heat.
  • Fast and reliable alarm detection before a complete fire breaks out.
  • Ability to accurately transmit specific data such as fire progress direction, alarm zone (stopped, moving in the direction of the device, away from the device) to the fighters..

As a major moment that takes fire protection to a new level in projects such as industrial facilities, highways and subway tunnels, AP Sensing - Fiberoptic Fire Detection Systems provides us with creative solutions.

 

Using only one fiber optic cable for thousands of points of detection is appropriate.

No region is left out of sight by AP Sensing-Fiberoptic Fire Detection Systems. The device enables continuous monitoring of the development and propagation of heats within the entire protected area in real time.
By reading thousands of heat values every 10 seconds along thousands of meters of fiber optic cables, the AP Sensing 'Linear Heat Series' based on the quantum mechanical RAMAN effect and patented measurement system (Code Correlation - OTDR) generates a perfect heat profile.

AP SENSING

We are provided with comprehensive security by AP Sensing, which uses the highest degree of system compatibility and its unique method of producing optical elements. Fault-free, continuous operation and quick assembly are completed with this system solution. Many components of the system are carefully selected, developed to provide the highest quality and the lowest failure rate

- Defining different targeted alarm criteria and sensitivities on the same sensor cable

The system allows us to define 5-parameter alarm criteria;

  • Static high value
  • Adaptive peak value (takes into account the temperature value of the environment, positive delta to the zone average in ° C)
  • 3-stage heat curve for different temperature rise characteristics (Temperature rise rate and constant value exceeding)

AP SENSING

Tunnel entry and exit points are more affected than the inner sections of the tunnel by temperature changes. Because of wind and air movements caused by mechanical fans, sections with constant high and low temperatures can be generated in the tunnel.
The AP Sensing 'Linear Heat Series' will identify various alarm sensitivities for different areas of the cable in order to cope with these variable temperature conditions. The system also allows the "negative" alarms used in the icing alert to be configured.

AP SENSING

-Having a large variety of solutions for products.

The capacity of the central unit includes 1,2,4 channel options. Solutions can be provided for a wide range of products, from 1 km to 40 km in unit capacity. For projects of several variable quantities, this helps us to step forward with the most optimal solutions.

AP SENSING

With fiber optic line control and Class-A connection, even when the fiber optic line is broken, the device will run continuously with a 100 percent redundant connection

- Even in areas with an explosive atmosphere, the sensor cable can be used without taking additional safety precautions. It has an ATEX certificate because of this functionality

The laser source (laser diode) of the unit is in 1M or 1 class according to IEC 60825-1: 2001. The laser source also conforms to FDA 21 CFR 1040.10, with the exception of Article 50 issued on July 26, 2001, prepared for laser aberrations. Reliability of the product according to IEC 60825-1: 2001, deviations according to CAN / CSA-C22.2 No.61010-04; Tested and approved according to UL 61010-1: 2004

AP SENSING

-It is a fire alarm system with the lowest operating and maintenance costs

-It is a fire alarm scheme with the lowest cost of service and repair

AP Sensing provides a safety principle based on a fiber optic cable acting as a linear temperature sensor with a high degree of accuracy. The sensor cable is a very easy to install, maintenance-free, very long-lasting cable that is thousands of meters long and can be used..

- The most suitable sensor cable options for the application.

The most acceptable form of sensor cable solution can be provided for the project, even if there is dirt, dust, corrosive atmospheres, organic vapors, extreme temperatures or nuclear waves in the environment. The life of all cables is 30 years even under the worst environmental conditions and does not require maintenance.

AP SENSING

- It has a simple and stable system architecture.

AP SENSING

AP SENSING PC = PC with DTS configurator
FP = Fire panel or scada system
UPS = Uninterruptible power supply or battery pack

- Ease of assembly and application.

With a suitable cable clamp or tension wire application, the sensor cable can be securely attached to a tunnel ceiling. If necessary, with the progress of construction work, the installation of the sensor cable can be carried out, otherwise the cable can be laid using a mobile cylinder block or roller stand. AP SENSING

 

To provide a suitable response characteristic, a distance between 15mm and 50mm should be left from the ceiling.

AP SENSING

- Having all the features designed for business safety.

The 'Linear Heat Series' AP Sensing has features built to provide trouble-free activity and flexible usage in hazardous areas under harsh conditions.

Specifications Advantages
Fast, accurate and reliable fire alarm Highest security and lowest false alarm rate, even in potentially explosive areas
Advanced technology in quality and working life Low service and maintenance costs
Freely programmable alarm criteria per zone The same sensor offers accurate and targeted detection with different alarm sensitivities and false alarm security on the cable
The sensor cable is resistant to environmental conditions and does not require maintenance Reduces operational costs by delivering maintenance-free, continuous service, including in hazardous areas
Sensor cable is light and flexible and can be installed simply It simplifies assembly, making it ideal for cable tunnels, conveyor belts, warehouses, and mid-floors
Sensor cable has the highest resistance up to 1000 ° C. Can effectively anticipate the extent and magnitude of the fire in order to implement fire precautions effectively
It has easy system integration, scaling and standard communication interfaces and protocols Easy commissioning with plug-and-play feature
Low power semiconductor laser and single receiver design Broad operating temperature range, maximum life-safe operation, low energy consumption.

 

- Easiest to integrate into existing management system.

You can easily incorporate the AP Sensing 'Linear Heat Series' into your management platform (such as SCADA systems). For this, direct communication can be provided using SCPI (Standard Commands for Programmable Interface) over Ethernet (TCP / IP) or the standard protocols Modbus, RS-232, RS-422, RS-485.

AP SENSING

With graphic software or scada integration, the exact coordinates of the fire location or hot-moving zone can be followed from the graphic software. The graphic program will display data such as the direction of the fire progress and the alarm zone (stopped, moving in the direction of the device, moving away from the device).

AP SENSING

- Zone alarm information can be monitored via relay contacts from the fire control panel (FCP).

The AP Sensing Fiber Optic DTS Unit has a separate programmable relay output for 256 different alarm zones based on 5 alarm criteria. Contact-based integration with fire systems can be achieved in this way

An additional relay extension module with 256 relay outputs per sensor cable can be connected to the main system to increase the 20 standard relay outputs. A simple connection is provided to the existing fire alarm center, thanks to the relay outputs

AP SENSING

- It performs pre-programmed control processes. For example, it can be integrated with ventilation activation, video systems, fire extinguishing systems.

The 'Linear Heat Series' management system of AP Sensing can be incorporated on a software or contact basis with protection control systems such as smoke evacuation and extinguishing, video management system (CCTV) or third party systems

AP SENSING

- AP Sensing ‘in ürün kalitesindeki lider¬liği; üstün tasarımına, kalitesini kanıtla¬mış yapı elemanlarına ve onlarca yıllık üretim deneyimine dayanmaktadır.

AP Sensing's leadership in product quality is based on its superior design, proven building elements and decades of manufacturing experience. Because of its design with low-power semiconductor components, long-life low-power semiconductor lasers, and a proprietary measurement process, the system has the lowest optical power loss in the fiber optic and linear heat detection systems industry ( Code Correlation).
AP Sensing "Linear Heat Series" has a patented system design with a single receiver design that guarantees long-term stability of measurement and does not allow any deviation from dual receiver concepts. This unique receiver model avoids the need to recalibrate the system, even after years of operation. Thanks to their extremely low optical power loss, the AP Sensing 'Linear Heat Series' systems are very secure in use and in service. Apsensing DTS systems, unlike other fiber optic, linear heat detectors, are classified as non-hazardous except in the event of wire breakage, so there is no risk in continuing to use them. In addition, it is possible to use the sensor cable in areas with explosive atmosphere without taking additional safety measures. Thanks to this feature, it has ATEX certificate.

  • Calculated MTBF value 33 years
  • Semiconductor laser with a 60-year lifetime with the pulse method
  • Tested for 100 million switching times, costing 63 years of use.

Agilent Technologies 20 years of OTDR experience, validated ICs and manufacturing processes are based on lifetime and efficiency with the lowest failure rate of optical test and measurement instruments

Regardless of the communication infrastructure, even if the communication network is disabled or built in a difficult to access area, the system does not need constant surveillance at all. After a power failure, the system restarts the measurements within 30 seconds. It works with the tested real-time operating system (vxWorks), maintaining device stability and is resistant to viruses.

Thanks to its LAN interface, it enables simultaneous intervention and monitoring from different remote points. It is the only solution that can connect 10km with a single unit, 40km without redundant sensor cable

The interface protocol is fully available for integration with custom programs. It can be used in any environment and does not require additional cooling.
It has the opportunity to work even in the wide temperature ranges of the industry, thanks to its superbly integrated optical elements. The laser components and receiver diodes are stable against heat and guarantee accurate measurement of all operating temperature ranges.

AP SENSING

A completely insulated inert gaseous block that protects against condensation, dust and moisture, surrounds all optical components in the system. In this way, regardless of environmental changes, a long-term stable activity is assured..

AP Sensing, with global service and organizational support, provides a wide variety of services and warranties. Every device and every system is supplied to our high quality standards and with a comprehensive worldwide service warranty.

In turkey, Matrix Building Control Systems is implemented as a high performance with strong engineering and technical service staff of the company. Matriks Building Control Systems and AP Sensing are the strategic partners of your success

- Certifications

AP Sensing fire detection systems have many internationally accepted standard approvals

AP SENSING

AP Sensing Fiber Optic Fire Detection System Some of Our References